<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-17 13-13-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 67 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 2.9 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 19077 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 2,36 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Jousikvartetto A-Molli Op. 51 Nro 2 (Brahms) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/17 13.12.48 Total samples: 19077 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,0 dBr MIN: 0,9 dBr AVE: 2,36 dBr % above 12,2 dBr: 0,0 Last value: 1,9 dBr (2024/10/17 13.12.47) 12.58 13.00 13.02 13.04 13.06 13.08 13.10 13.12 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]